Share to
ZW68-12 Green CB
Still deciding? Get samples first, Contact US !
View similar products
Tag list
- Product Details
-
ZW68-12/T630-20 outdoor high-voltage AC circuit breaker is an outdoor high-voltage AC switchgear with three-phase AC 50Hz and rated voltage of 12kV, which is mainly used for breaking and closing load current, overload current and short-circuit current in power system. The products completely comply with GB11022, GB1984, DL/T402 and the general technical specifications of 12kV-24kV outdoor pole-mounted circuit breakers of State Grid Corporation of China, and have passed all type tests. It is suitable for protection and control in power distribution systems of substations and industrial and mining enterprises, and is more suitable for rural power grids and places with frequent operation. It can also be used as a sectional switch of a power grid, and can realize distribution network automation after being added with a controller.
Product Details:
ㆍ The environment-friendly dry air is adopted as an insulating medium, so that the use of sulfur hexafluoride is avoided, low-temperature liquefaction risk is avoided, ensuring environment-friendly, safe and maintenance-free performance.
ㆍ The pole-mounted circuit breaker and the FTU feeder terminal can operate normally at the air temperature between the minimum temperature of -40℃ and the maximum temperature of +55℃, and have the characteristics of anti-condensation and anti-pollution, and are specially used for outdoor operation environment.
ㆍ The vacuum circuit breaker, the disconnecting switch, the current transformer, the voltage sensor and the operating mechanism are all sealed in the box body by adopting the fully-insulated, fully-sealed and miniaturized design, so that the vacuum circuit breaker, the disconnecting switch, the current transformer, the voltage sensor and the operating mechanism are all sealed in the box body, the structure is compact, the protection level is high, and the installation and the transportation are convenient.
ㆍ The outer components are high-quality aviation plug-ins, which are convenient to connect and reliable to plug in. The current circuit has the function of anti-open circuit, which can be inserted and unplugged at will during the line operation.
ㆍ The product has intelligent function and can realize the automatic functions of distribution network such as line loss measurement, earthing fault line selection and line protection. The FTU feeder terminal is configured to support various power communication protocols such as wireless public network and optical fiber Ethernet. Configure backup power supply to ensure switch control and communication power consumption within 48 hours after line power failure.
Technical ParametersNo. Item Unit Value 1 Rated voltage kV 12 2 Rated insulation level 1min power frequency withstand voltage (phase-to-phase, phase-to-earth (wet test)/isolating distance) kV 42/48 See ★Note 1 Lightning impulse withstand voltage (phase, phase/isolating distance) 75/85 3 Rated frequency Hz 50 4 Rated current A 630 5 Rated short-time withstand current kA 20 6 Rated peak withstand current kA 50 7 Rated short-circuit current dduration s 4 8 Rated short-circuit breaking times Time 30 9 Rated short-circuit breaking current Effective value of AC component kA 20 DC component 52% 10 Rated operating sequence O-0.3s-CO-180s-CO 11 Rated short circuit making current kA 50 12 Rated out-of-step breaking current 5 13 Rated out-of-phase breaking current kA 17.4 14 Rated capacitive switching current (Class C2) Rated cable charging breaking current (effective value) A 25 15 Rated resistance of main circuit μΩ ≤200 16 Mechanical life Circuit Breaker (CB) Time 10000 Disconnecting switch (manual) 3000 17 1min power frequency withstand voltage of secondary circuit kV 2 18 Auxiliary and control loop Rated supply voltage V DC:220、110、48
AC:220、110Rated supply frequency Hz 50 19 Terminal static load Static horizontal force N Longitudinal: 500; Horizontal: 400 Static vertical force Up: 500; Down: 500 20 Rated pressure (20℃ absolute pressure) Mpa 0.02 21 Annual leakage rate Year ≤0.1% 22 Partial discharge pC <20 23 Moisture content of dry air (20℃) μL/L ≤150(handover acceptance value) ≤300(allowable operating value) 24 Protection level oof gas-filling compartments IP67 25 Overall dimension mm (LxWxH) 920x720x830 26 Weight 175 kg